Review



nikon stedycon microscope operating  (Nikon)


Bioz Verified Symbol Nikon is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Nikon nikon stedycon microscope operating
    Nikon Stedycon Microscope Operating, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 60152 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/stedycon+system/Objectives/pm40586369-242-8-8
    Average 99 stars, based on 60152 article reviews
    nikon stedycon microscope operating - by Bioz Stars, 2026-10
    99/100 stars

    Images

    Related Articles

    Super-Resolution Microscopy:

    Article Title: Physiologic and Nanoscale Distinctions Define Glutamatergic Synapses in Tonic vs Phasic Neurons
    Article Snippet: .. STED super resolution microscopy was performed with an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope using four excitation lasers (640, 561, 488, and 405 nm), a pulsed STED laser of 775 nm, and three avalanche photodiode detectors that operate in a single photon counting mode. .. Before imaging, samples were mounted either in VectaShield (Vector Laboratories, for confocal) or ProLong Glass Antifade Mountant (Fisher Scientific, for stimulated emission depletion [STED]).

    Microscopy:

    Article Title: Physiologic and Nanoscale Distinctions Define Glutamatergic Synapses in Tonic vs Phasic Neurons
    Article Snippet: .. STED super resolution microscopy was performed with an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope using four excitation lasers (640, 561, 488, and 405 nm), a pulsed STED laser of 775 nm, and three avalanche photodiode detectors that operate in a single photon counting mode. .. Before imaging, samples were mounted either in VectaShield (Vector Laboratories, for confocal) or ProLong Glass Antifade Mountant (Fisher Scientific, for stimulated emission depletion [STED]).

    Article Title: Distinct input-specific mechanisms enable presynaptic homeostatic plasticity.
    Article Snippet: .. Briefly, STED imaging was performed using an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope equipped with four excitation lasers (640, 561, 488, and 405 nm), a pulsed STED laser at 775 nm, and three avalanche photodiode detectors that operate in a single photon counting mode. .. Multichannel 2D STED images were acquired using a 100× Nikon Plan APO 1.45 NA oil immersion objective with a 15- nm fixed pixel size and a 10- μs dwell time using 15× line accumulation in photon counting mode and a field of view of one to two boutons.

    Article Title: Distinct input-specific mechanisms enable presynaptic homeostatic plasticity
    Article Snippet: .. Briefly, STED imaging was performed using an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope equipped with four excitation lasers (640, 561, 488, and 405 nm), a pulsed STED laser at 775 nm, and three avalanche photodiode detectors that operate in a single photon counting mode. .. Multichannel 2D STED images were acquired using a 100x Nikon Plan APO 1.45 NA oil immersion objective with 15 nm fixed pixel size and 10 μsec dwell time using 15x line accumulation in photon counting mode and field of view of 1-2 boutons.

    Article Title: Resolving synaptic events using subsynaptically targeted GCaMP8 variants
    Article Snippet: .. Briefly, STED imaging was performed with an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope. ..

    Article Title: Distinct input-specific mechanisms enable presynaptic homeostatic plasticity
    Article Snippet: .. Briefly, STED imaging was performed using an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope equipped with four excitation lasers (640, 561, 488, and 405 nm), a pulsed STED laser at 775 nm, and three avalanche photodiode detectors that operate in a single photon counting mode. .. Multichannel 2D STED images were acquired using a 100× Nikon Plan APO 1.45 NA oil immersion objective with a 15-nm fixed pixel size and a 10-μs dwell time using 15× line accumulation in photon counting mode and a field of view of one to two boutons.

    Article Title: Resolving synaptic events using subsynaptically targeted GCaMP8 variants
    Article Snippet: .. Briefly, STED imaging was performed with an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope. ..

    Imaging:

    Article Title: Distinct input-specific mechanisms enable presynaptic homeostatic plasticity.
    Article Snippet: .. Briefly, STED imaging was performed using an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope equipped with four excitation lasers (640, 561, 488, and 405 nm), a pulsed STED laser at 775 nm, and three avalanche photodiode detectors that operate in a single photon counting mode. .. Multichannel 2D STED images were acquired using a 100× Nikon Plan APO 1.45 NA oil immersion objective with a 15- nm fixed pixel size and a 10- μs dwell time using 15× line accumulation in photon counting mode and a field of view of one to two boutons.

    Article Title: Distinct input-specific mechanisms enable presynaptic homeostatic plasticity
    Article Snippet: .. Briefly, STED imaging was performed using an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope equipped with four excitation lasers (640, 561, 488, and 405 nm), a pulsed STED laser at 775 nm, and three avalanche photodiode detectors that operate in a single photon counting mode. .. Multichannel 2D STED images were acquired using a 100x Nikon Plan APO 1.45 NA oil immersion objective with 15 nm fixed pixel size and 10 μsec dwell time using 15x line accumulation in photon counting mode and field of view of 1-2 boutons.

    Article Title: Resolving synaptic events using subsynaptically targeted GCaMP8 variants
    Article Snippet: .. Briefly, STED imaging was performed with an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope. ..

    Article Title: Distinct input-specific mechanisms enable presynaptic homeostatic plasticity
    Article Snippet: .. Briefly, STED imaging was performed using an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope equipped with four excitation lasers (640, 561, 488, and 405 nm), a pulsed STED laser at 775 nm, and three avalanche photodiode detectors that operate in a single photon counting mode. .. Multichannel 2D STED images were acquired using a 100× Nikon Plan APO 1.45 NA oil immersion objective with a 15-nm fixed pixel size and a 10-μs dwell time using 15× line accumulation in photon counting mode and a field of view of one to two boutons.

    Article Title: Cell penetrating peptides are versatile tools for enhancing multimodal uptake into cells from pest insects.
    Article Snippet: Cell penetrating peptides (CPPs) are small peptides defined by their ability to deliver molecular cargo into cells.. While the subject of frequent investigation for pharmaceutical drug delivery, little consideration has been given to the possibility of CPPs for use as insecticides or insecticide enhancers.. Here, we characterize the entry of four fluorescently tagged CPPs into two insect cell lines and dissected midgut tissues in terms of both total quantity and mode of penetration.

    Article Title: Resolving synaptic events using subsynaptically targeted GCaMP8 variants
    Article Snippet: .. Briefly, STED imaging was performed with an Abberior STEDYCON system mounted on a Nikon Eclipse FN1 upright microscope. ..



    Similar Products

    90
    abberior instruments stedycon sted microscope
    Stedycon Sted Microscope, supplied by abberior instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/stedycon+system/stedycon+sted+microscope/pm40663602-313-6-9
    Average 90 stars, based on 1 article reviews
    stedycon sted microscope - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    abberior instruments four detector abberior stedycon sted unit
    (A) Representative FACS plot of cell sorting strategy to isolate purified oxLDL + and oxLDL - neutrophils. ( B ) Reactome pathway analysis of proteins increased in oxLDL + subset in the proteomics data. ( C ) Heatmap of selected differentially expressed proteins in oxLDL - and oxLDL + neutrophil populations. ( D ) 100x <t>STED</t> immunofluorescent imaging of peritoneal cells isolated from zymosan and oxLDL-Dil IP-injected mice and stained for phalloidin. Cells were also stained and checked for Ly6G expression, which is not shown for clarity of phalloidin stain. Representative oxLDL + (left) and oxLDL - (right) cells are shown. ( E ) In vitro oxLDL-Dil uptake in bone marrow enriched neutrophils treated with cytochalasin D. ( F ) Transwell migration assay of oxLDL - and oxLDL + neutrophils sorted from peritoneal cells following zymosan and oxLDL-Dil IP injection. ( E-F ) All symbols represent independent experiments. Data are expressed as mean ± SEM. Statistical differences were calculated by one-way ANOVA for F and two-way ANOVA for G. * ≤ 0.05, ** ≤ 0.01,***≤0.001
    Four Detector Abberior Stedycon Sted Unit, supplied by abberior instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/stedycon+system/abberior+stedycon/bio_rxiv__2025__07__09__663961-150-10-11
    Average 90 stars, based on 1 article reviews
    four detector abberior stedycon sted unit - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    abberior instruments stedycon sted microscopes
    (A) Representative FACS plot of cell sorting strategy to isolate purified oxLDL + and oxLDL - neutrophils. ( B ) Reactome pathway analysis of proteins increased in oxLDL + subset in the proteomics data. ( C ) Heatmap of selected differentially expressed proteins in oxLDL - and oxLDL + neutrophil populations. ( D ) 100x <t>STED</t> immunofluorescent imaging of peritoneal cells isolated from zymosan and oxLDL-Dil IP-injected mice and stained for phalloidin. Cells were also stained and checked for Ly6G expression, which is not shown for clarity of phalloidin stain. Representative oxLDL + (left) and oxLDL - (right) cells are shown. ( E ) In vitro oxLDL-Dil uptake in bone marrow enriched neutrophils treated with cytochalasin D. ( F ) Transwell migration assay of oxLDL - and oxLDL + neutrophils sorted from peritoneal cells following zymosan and oxLDL-Dil IP injection. ( E-F ) All symbols represent independent experiments. Data are expressed as mean ± SEM. Statistical differences were calculated by one-way ANOVA for F and two-way ANOVA for G. * ≤ 0.05, ** ≤ 0.01,***≤0.001
    Stedycon Sted Microscopes, supplied by abberior instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/stedycon+system/stedycon+sted+microscope/pmc09907107__pnas__2215799119__sapp-122-11-17
    Average 90 stars, based on 1 article reviews
    stedycon sted microscopes - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    abberior instruments stedycon smart control sted microscopy software
    (A) Representative FACS plot of cell sorting strategy to isolate purified oxLDL + and oxLDL - neutrophils. ( B ) Reactome pathway analysis of proteins increased in oxLDL + subset in the proteomics data. ( C ) Heatmap of selected differentially expressed proteins in oxLDL - and oxLDL + neutrophil populations. ( D ) 100x <t>STED</t> immunofluorescent imaging of peritoneal cells isolated from zymosan and oxLDL-Dil IP-injected mice and stained for phalloidin. Cells were also stained and checked for Ly6G expression, which is not shown for clarity of phalloidin stain. Representative oxLDL + (left) and oxLDL - (right) cells are shown. ( E ) In vitro oxLDL-Dil uptake in bone marrow enriched neutrophils treated with cytochalasin D. ( F ) Transwell migration assay of oxLDL - and oxLDL + neutrophils sorted from peritoneal cells following zymosan and oxLDL-Dil IP injection. ( E-F ) All symbols represent independent experiments. Data are expressed as mean ± SEM. Statistical differences were calculated by one-way ANOVA for F and two-way ANOVA for G. * ≤ 0.05, ** ≤ 0.01,***≤0.001
    Stedycon Smart Control Sted Microscopy Software, supplied by abberior instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/stedycon+system/stedycon+confocal+microscope/pm40597205-124-13-16
    Average 90 stars, based on 1 article reviews
    stedycon smart control sted microscopy software - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    99
    Nikon nikon stedycon microscope operating
    (A) Representative FACS plot of cell sorting strategy to isolate purified oxLDL + and oxLDL - neutrophils. ( B ) Reactome pathway analysis of proteins increased in oxLDL + subset in the proteomics data. ( C ) Heatmap of selected differentially expressed proteins in oxLDL - and oxLDL + neutrophil populations. ( D ) 100x <t>STED</t> immunofluorescent imaging of peritoneal cells isolated from zymosan and oxLDL-Dil IP-injected mice and stained for phalloidin. Cells were also stained and checked for Ly6G expression, which is not shown for clarity of phalloidin stain. Representative oxLDL + (left) and oxLDL - (right) cells are shown. ( E ) In vitro oxLDL-Dil uptake in bone marrow enriched neutrophils treated with cytochalasin D. ( F ) Transwell migration assay of oxLDL - and oxLDL + neutrophils sorted from peritoneal cells following zymosan and oxLDL-Dil IP injection. ( E-F ) All symbols represent independent experiments. Data are expressed as mean ± SEM. Statistical differences were calculated by one-way ANOVA for F and two-way ANOVA for G. * ≤ 0.05, ** ≤ 0.01,***≤0.001
    Nikon Stedycon Microscope Operating, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/stedycon+system/Objectives/pm40586369-242-8-8
    Average 99 stars, based on 1 article reviews
    nikon stedycon microscope operating - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    90
    abberior instruments super-resolution stedycon microscope
    (A) Representative FACS plot of cell sorting strategy to isolate purified oxLDL + and oxLDL - neutrophils. ( B ) Reactome pathway analysis of proteins increased in oxLDL + subset in the proteomics data. ( C ) Heatmap of selected differentially expressed proteins in oxLDL - and oxLDL + neutrophil populations. ( D ) 100x <t>STED</t> immunofluorescent imaging of peritoneal cells isolated from zymosan and oxLDL-Dil IP-injected mice and stained for phalloidin. Cells were also stained and checked for Ly6G expression, which is not shown for clarity of phalloidin stain. Representative oxLDL + (left) and oxLDL - (right) cells are shown. ( E ) In vitro oxLDL-Dil uptake in bone marrow enriched neutrophils treated with cytochalasin D. ( F ) Transwell migration assay of oxLDL - and oxLDL + neutrophils sorted from peritoneal cells following zymosan and oxLDL-Dil IP injection. ( E-F ) All symbols represent independent experiments. Data are expressed as mean ± SEM. Statistical differences were calculated by one-way ANOVA for F and two-way ANOVA for G. * ≤ 0.05, ** ≤ 0.01,***≤0.001
    Super Resolution Stedycon Microscope, supplied by abberior instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/stedycon+system/stedycon+microscope/pm40541899-172-70-62
    Average 90 stars, based on 1 article reviews
    super-resolution stedycon microscope - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Carl Zeiss confocal laser scanning microscope lsm880 airyscan with stedycon
    (A) Representative FACS plot of cell sorting strategy to isolate purified oxLDL + and oxLDL - neutrophils. ( B ) Reactome pathway analysis of proteins increased in oxLDL + subset in the proteomics data. ( C ) Heatmap of selected differentially expressed proteins in oxLDL - and oxLDL + neutrophil populations. ( D ) 100x <t>STED</t> immunofluorescent imaging of peritoneal cells isolated from zymosan and oxLDL-Dil IP-injected mice and stained for phalloidin. Cells were also stained and checked for Ly6G expression, which is not shown for clarity of phalloidin stain. Representative oxLDL + (left) and oxLDL - (right) cells are shown. ( E ) In vitro oxLDL-Dil uptake in bone marrow enriched neutrophils treated with cytochalasin D. ( F ) Transwell migration assay of oxLDL - and oxLDL + neutrophils sorted from peritoneal cells following zymosan and oxLDL-Dil IP injection. ( E-F ) All symbols represent independent experiments. Data are expressed as mean ± SEM. Statistical differences were calculated by one-way ANOVA for F and two-way ANOVA for G. * ≤ 0.05, ** ≤ 0.01,***≤0.001
    Confocal Laser Scanning Microscope Lsm880 Airyscan With Stedycon, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/stedycon+system/880+confocal+lsm+microscope/pm40527084-59-7-6
    Average 90 stars, based on 1 article reviews
    confocal laser scanning microscope lsm880 airyscan with stedycon - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    (A) Representative FACS plot of cell sorting strategy to isolate purified oxLDL + and oxLDL - neutrophils. ( B ) Reactome pathway analysis of proteins increased in oxLDL + subset in the proteomics data. ( C ) Heatmap of selected differentially expressed proteins in oxLDL - and oxLDL + neutrophil populations. ( D ) 100x STED immunofluorescent imaging of peritoneal cells isolated from zymosan and oxLDL-Dil IP-injected mice and stained for phalloidin. Cells were also stained and checked for Ly6G expression, which is not shown for clarity of phalloidin stain. Representative oxLDL + (left) and oxLDL - (right) cells are shown. ( E ) In vitro oxLDL-Dil uptake in bone marrow enriched neutrophils treated with cytochalasin D. ( F ) Transwell migration assay of oxLDL - and oxLDL + neutrophils sorted from peritoneal cells following zymosan and oxLDL-Dil IP injection. ( E-F ) All symbols represent independent experiments. Data are expressed as mean ± SEM. Statistical differences were calculated by one-way ANOVA for F and two-way ANOVA for G. * ≤ 0.05, ** ≤ 0.01,***≤0.001

    Journal: bioRxiv

    Article Title: Neutrophil TLR2 signaling promotes lipid accumulation and vascular plaque growth

    doi: 10.1101/2025.07.09.663961

    Figure Lengend Snippet: (A) Representative FACS plot of cell sorting strategy to isolate purified oxLDL + and oxLDL - neutrophils. ( B ) Reactome pathway analysis of proteins increased in oxLDL + subset in the proteomics data. ( C ) Heatmap of selected differentially expressed proteins in oxLDL - and oxLDL + neutrophil populations. ( D ) 100x STED immunofluorescent imaging of peritoneal cells isolated from zymosan and oxLDL-Dil IP-injected mice and stained for phalloidin. Cells were also stained and checked for Ly6G expression, which is not shown for clarity of phalloidin stain. Representative oxLDL + (left) and oxLDL - (right) cells are shown. ( E ) In vitro oxLDL-Dil uptake in bone marrow enriched neutrophils treated with cytochalasin D. ( F ) Transwell migration assay of oxLDL - and oxLDL + neutrophils sorted from peritoneal cells following zymosan and oxLDL-Dil IP injection. ( E-F ) All symbols represent independent experiments. Data are expressed as mean ± SEM. Statistical differences were calculated by one-way ANOVA for F and two-way ANOVA for G. * ≤ 0.05, ** ≤ 0.01,***≤0.001

    Article Snippet: For super resolution imaging, slides were imaged using a four detector Abberior STEDYCON STED unit.

    Techniques: FACS, Purification, Imaging, Isolation, Injection, Staining, Expressing, In Vitro, Transwell Migration Assay